    The Optimal Design of the Air Distribution System for a Library Located in the Subtropical Area

    Thumbnail
    View/Open
    tsea-24-1405.pdf (1.186Mb)
    Date
    2025
    Author
    Shih, Yang-Cheng
    Ali Zargar, Omid
    Huang, Yu-Kai
    Hu, Shih-Cheng
    Leggett, Graham
    Metadata
    Show full item record
    Abstract
    In this study, the critical operation parameters related to the heating, ventilation, and air conditioning (HVAC) system of a campus library are numerically optimized. The objective of this study is to improve the standards related to thermal comfort and indoor air quality (IAQ) of the campus library. As a result, the library's energy consumption is significantly reduced with this new HVAC system design. The computational fluid dynamics software ansys fluent and experimental measurement are used to verify the effects of changes in velocity, temperature, and relative humidity (RH) of the air supply system (three operating parameters) on the ventilation efficiency. The ventilation efficiency is also assessed by parameters such as AC power consumption, the predicted mean vote (PMV) for thermal comfort, and CO2 concentration for IAQ (three-target performances). A response surface was developed numerically using ansys designxplorer to analyze the relationship between those three operating parameters and the three mentioned target performance characteristics. The optimization results show that the target performance of CO2 concentration should be <1000 ppm; in addition, the PMV should be in the range of −0.5 < PMV < 0.5. The results show that if air supply velocity, temperature, and RH are set to 1.0 m/s, 23 °C, and 40%, respectively, then the library electricity consumption (and cost) can be significantly reduced by up to 22.3%.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4310723
    Collections
    • Journal of Thermal Science and Engineering Applications

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV