• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Energy Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Energy Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Performance Evaluation of Chiller Unit with Gas Bearings Based on Energy, Exergy, Economic, and Environmental Analyses

    Thumbnail
    View/Open
    JLEED9.EYENG-5618.pdf (3.300Mb)
    Date
    2025
    Author
    Jieming Gong
    Shicheng Ying
    Junnan Song
    Guangbin Liu
    Qichao Yang
    Yuanyang Zhao
    Liansheng Li
    Jing Wang
    Metadata
    Show full item record
    Abstract
    Chilled water units using centrifugal compressors with gas bearings are an important research direction, but the necessary additional refrigerant circulation for gas bearings and motor cooling increases the design and operation difficulty, and therefore gas-suspended chiller units have few applications in the building sector. By establishing a system model based on energy, exergy, economic, and environmental analyses, this paper analyzes and compares the coefficient of performance (COP), exergy efficiency, power consumption, and economy of three refrigeration cycles under different operating conditions. The results showed that the system performance is insensitive to the supply pressure of gas bearings due to the relatively small mass flow rate. The enhanced gas-bearing-assisted vapor compression chilled water system (EGVC) demonstrated superior COP and exergy efficiency, and lower CO2 emissions compared with the gas-bearing-assisted vapor compression chilled water system (GVCW) and dual-economizer gas-bearing-assisted vapor compression chilled water system (DGVC) for the various evaporation temperatures and ambient temperatures. Regardless of the system, the total exergy loss of the system was mainly from the condenser, accounting for approximately 40% of the total. Both the economic cost and total equal warming impact (TEWI) values of the system decreased with the evaporation temperature but increased with the ambient temperature. Specifically, the EGVC showed slightly higher economic cost and lower TEWI values than other systems. The performance parameters of the system were sensitive to the evaporation temperature for the three systems.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4309615
    Collections
    • Journal of Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV