    Optimization of the Joint Structure Between Asphalt Concrete Core and Concrete Plinth in Earthen Dams Based on the Response Surface Method

    Thumbnail
    View/Open
    IJGNAI.GMENG-10123.pdf (8.042Mb)
    Date
    2025
    Author
    Weifeng Cao
    Lifeng Wen
    Yanlong Li
    Zheng Si
    Yunhe Liu
    Mingming Rao
    Metadata
    Show full item record
    Abstract
    The joint structure between the asphalt concrete core and the concrete plinth is a critical and vulnerable part of the asphalt concrete core dam (ACCD). Shape parameters of the core–plinth joint structure are directly related to joint structure behavior and thus affect the core safety, but there is currently a lack of relevant quantitative research. In this paper, the shape parameters of the joint structure were optimized to obtain an economical joint form under the condition of ensuring the stress safety of the joint structure. Abutment slope ratio i, core enlarged angle θ, and depth of the core embedding into the plinth h were taken as optimization parameters. The maximum shear stress, maximum tensile stress, and minimum arch effect of the core were taken as constraint conditions, and the joint structure volume was taken as the objective function to establish a mathematical optimization model for the joint structure. The regression relationship between the constraint conditions and the joint structure parameters was fitted based on the central composite design and response surface method. A three-dimensional zone of joint structure parameters that can satisfy the constraints was further constructed. Combined with the linear programming method, an optimization calculation method for joint structure parameters was proposed. Taking the dam with the highest core among the ACCDs that have been built as an engineering example, an optimization analysis of the joint structure between the core and plinth was conducted. The results indicated that the stress and the arch effect of the joint structure improve as the abutment slope becomes gentler. As h increases, the arch effect and shear stress at the joint weaken. The increase in θ will increase the possibility of core shear failure and make the core suffer a stronger arch effect. Compared with the original engineering (θ and h are 75.96° and 0.3 m, respectively), when the θ and h are set as 80° and 0.39 m, the joint structure volume reduces by 6.67% under the condition of i of 1:0.33, which can achieve better economic efficiency under the premise of satisfying the core safety.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4309421
    Collections
    • International Journal of Geomechanics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV