Show simple item record

dc.contributor.authorManon, Bas-dit-Nugues
dc.contributor.authorKetani, Teddy
dc.contributor.authorBastard, Claire
dc.contributor.authorRosi, Giuseppe
dc.contributor.authorLomani, Hugues Albini
dc.contributor.authorFlouzat-Lachaniette, Charles-Henri
dc.contributor.authorDubory, Arnaud
dc.contributor.authorHaïat, Guillaume
dc.date.accessioned2025-08-20T09:37:35Z
dc.date.available2025-08-20T09:37:35Z
dc.date.copyright5/5/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.issn0148-0731
dc.identifier.otherbio_147_06_064502.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308581
dc.description.abstractHigh tibial osteotomy is a common procedure for knee osteoarthritis during which the surgeon partially opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on their proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this ex vivo study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone and vice versa. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively, the video and the surgeon; the surgeon and the algorithm) is 1.0±1.5 impacts (respectively, 0.5±0.6 impacts; 1.4±1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6±2.6 impacts (respectively, 3.9±2.4 impacts; 0.8±0.9 impacts), and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAn Instrumented Hammer to Detect the Bone Transitions During an High Tibial Osteotomy: An Animal Study
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue6
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4068372
dc.journal.fristpage64502-1
dc.journal.lastpage64502-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2025:;volume( 147 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record