Show simple item record

dc.contributor.authorNatarajan, Thangam
dc.contributor.authorHusain, Zainab
dc.contributor.authorCoppin, Peter W.
dc.contributor.authorSteinman, David A.
dc.date.accessioned2025-08-20T09:33:33Z
dc.date.available2025-08-20T09:33:33Z
dc.date.copyright3/26/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.issn0148-0731
dc.identifier.otherbio_147_05_054501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308477
dc.description.abstractTopological features of time-dependent, three-dimensional (3D) vector flow fields, such as wall shear stress (WSS) fixed points, are considered surrogates of pathological blood flow dynamics in cardiovascular diseases. Fixed-point visualizations are typically constrained to two-dimensional (2D) spaces, yet they aim to display complex spatiotemporal (four-dimensional (4D)) dynamics. There is a need for visualization strategies to reduce occlusion and reliance on animations to allow the detection of holistic flow patterns. Using intracranial aneurysms as a use case, we present the fixed-point carousel, a novel approach to visually depicting the “4D” nature of WSS fixed points via (1) topographic mapping of the 3D aneurysm sac to overcome occlusion while preserving fixed-point distances and sac morphological features; and (2) arranging these into a carousel model to present with temporal dimension holistically. Examples are presented for image-based computational fluid dynamic (CFD) models of intracranial aneurysms, illuminating the intricate and distinct fixed-point trajectories and interactions, a necessary step toward understanding the volumetric flow manifolds that drive them for this and other cardiovascular—and potentially nonbiomedical—fluid dynamics applications.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFour-Dimensional Visualization of Topological Fixed Points in Pulsatile Cardiovascular Flows
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue5
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4068078
dc.journal.fristpage54501-1
dc.journal.lastpage54501-10
dc.page10
dc.treeJournal of Biomechanical Engineering:;2025:;volume( 147 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record