Show simple item record

dc.contributor.authorLi, Hao
dc.contributor.authorXie, Haitao
dc.contributor.authorKang, Shujing
dc.contributor.authorXu, Kuixue
dc.contributor.authorXie, Meiming
dc.contributor.authorXie, Haiqiong
dc.contributor.authorCai, Xu
dc.contributor.authorWei, Kai
dc.date.accessioned2025-08-20T09:29:56Z
dc.date.available2025-08-20T09:29:56Z
dc.date.copyright3/18/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.issn0148-0731
dc.identifier.otherbio_147_05_051001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308378
dc.description.abstractTotal talar replacement (TTR) with an additively manufactured personalized total talar prosthesis (TTP) is an emerging treatment for ankle disorders. However, how to enhance the ankle stability after TTR, which usually raises the ankle instability, has not been explored. This study constructed a set of specific numerical models to investigate the effects of TTR and oversized TTPs on the ankle stability, including inversion, eversion, and anterior stability. The oversized TTPs include TTP-FP1.5 and TTP-FP3 scaled the identical TTP0 by 1.5% and 3.0% along the frontal axis, and TTP-VP1.5 and TTP-VP3 scaled TTP0 by 1.5% and 3.0% along the vertical axis. The numerical results identify that under varus/valgus force, the TTP-FP1.5 and TTP-FP3 produce smaller talar tilt angles compared with that of TTP0, as the inversion and eversion stability are significantly enhanced. Furthermore, TTP-VP1.5 and TTP-VP3 can provide larger contact force to the tibia, providing better anterior stability under anterior drawer force. Additionally, the increased contact force of TTP-VP1.5 and TTP-VP3 with the tibial cartilage enhances the eversion stability. Besides, the increase of TTP size along the vertical axis will weaken the inversion stability under low loads, as this scaling might have compromised the stability of the subtalar joint. The present numerical study systematically investigates the effect of different ways of increasing TTP size on ankle stability after TTP.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleOversized Total Talar Prosthesis Enhances the Ankle Stability After Total Talus Replacement by Finite Element Analysis
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue5
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4068008
dc.journal.fristpage51001-1
dc.journal.lastpage51001-9
dc.page9
dc.treeJournal of Biomechanical Engineering:;2025:;volume( 147 ):;issue: 005
dc.contenttypeFulltext