Show simple item record

dc.contributor.authorLiu, Y.
dc.contributor.authorSchekman, S. W.
dc.contributor.authorZhang, K.
dc.contributor.authorLu, T. J.
dc.contributor.authorKim, T.
dc.date.accessioned2025-08-20T09:28:29Z
dc.date.available2025-08-20T09:28:29Z
dc.date.copyright12/16/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn2832-8450
dc.identifier.otherht_147_04_041801.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308339
dc.description.abstractThe thermofluidic effectiveness of a microtube cold plate with sidewall modification has been disputed. This study settles the dispute by detailing how such sidewall modification—hemi-circular cavities arranged along a straight circular microtube embedded with a cold plate—enhances cooling. To this end, a series of numerical simulations for a single microtube cold plate in a practical range of Reynolds numbers (20 ≤ ReD ≤ 200) are carried out. For experimental validation, flow development and pressure drop in both reference and modified microtubes are characterized respectively by microparticle image velocimetry and pneumatic pressure measurements, while surface temperatures on both cold plates' substrates subjected to uniform heat flux are measured by infrared thermography. The results agree that the boundary layer development in each throat, a short straight coolant passage that connects successive cavities, indeed enhances the cooling in the cold plate with the wall modification. However, in contrast to its sole contribution argued previously, a non-negligible source of thermal enhancement is identified. The coolant flow approaching each throat noticeably bifurcates across the throat and cavity sidewall. Thereafter, a boundary layer develops along concave sidewalls and subsequently circulates within each cavity, generating high wall shear stresses upstream of each throat and significantly elevating local cooling. In conclusion, the local cooling both “upstream” and “in” throats plays a dominant role in enhancing the overall cooling in the cold plate with wall modification, up to 40% over the reference microtube cold plate in the Reynolds number range considered.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleMechanisms of Enhanced Cooling by Sidewall Modification in a Microtube Cold Plate
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue4
dc.journal.titleASME Journal of Heat and Mass Transfer
dc.identifier.doi10.1115/1.4067158
dc.journal.fristpage41801-1
dc.journal.lastpage41801-16
dc.page16
dc.treeASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record