Show simple item record

dc.contributor.authorHassan, Motaz
dc.contributor.authorWasir, Amanpreet Singh
dc.contributor.authorMahajan, Ajay
dc.date.accessioned2025-08-20T09:19:51Z
dc.date.available2025-08-20T09:19:51Z
dc.date.copyright4/11/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.issn1932-6181
dc.identifier.othermed_019_02_024503.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308099
dc.description.abstractUreteroscopy with stone extraction devices is a common treatment for urolithiasis but carries risks, such as ureteral wall avulsion due to excessive withdrawal forces. These forces arise from friction between the stone basket and the ureteral wall, and existing devices lack real-time feedback, relying on the surgeon's tactile judgment, which may lead to preventable injuries. This study addresses this gap by developing a system to measure and monitor withdrawal forces during stone retrieval. The system integrates a linear variable differential transformer (LVDT) sensor, Arduino microcontroller, calibrated spring mechanism, and a kidney stone basket, providing force feedback categorized into safe, cautionary, and high-risk zones. Bench-top trials demonstrated its reliability, with force measurement accuracy (variance ±0.05 N) and classification into safe (<5.396 N), cautious (5.396 N–9.809 N), and dangerous (>9.809 N) zones, in line with thresholds for tissue damage reported in literature. The system demonstrated force control within safe thresholds, reducing excessive withdrawal force incidents by an estimated 30% compared to conventional tactile-based extraction, potentially lowering the risk of ureteral injuries such as perforation and avulsion. Additionally, this feedback mechanism can be incorporated into ureteroscopy simulators and surgical training programs, allowing residents to visualize force applications in real-time and develop safer extraction techniques. By providing quantitative force thresholds, the system enables objective skill assessment and structured training exercises, helping residents refine techniques before performing procedures. Future research will focus on clinical validation and expanding the system's capabilities to improve surgical outcomes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleSmart Kidney Stone Basket: A Proof of Concept With Digital Feedback Force Monitoring
dc.typeJournal Paper
dc.journal.volume19
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4068328
dc.journal.fristpage24503-1
dc.journal.lastpage24503-7
dc.page7
dc.treeJournal of Medical Devices:;2025:;volume( 019 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record