Show simple item record

dc.contributor.authorVictor Vestman
dc.contributor.authorHarry White
dc.contributor.authorPeter Collin
dc.contributor.authorHeikki Lilja
dc.contributor.authorTimo Tirkkonen
dc.contributor.authorMikko Peltomaa
dc.contributor.authorJavier Jordan
dc.contributor.authorJacques Berthellemy
dc.contributor.authorRobert Hällmark
dc.date.accessioned2025-08-17T23:07:01Z
dc.date.available2025-08-17T23:07:01Z
dc.date.copyright8/1/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.otherJSDCCC.SCENG-1644.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4307928
dc.description.abstractSomething as simple as the use of lateral bracing for a steel I-girder bridge should be consistent across the globe. However, an investigation into the bridge standards of different countries in Europe and North America revealed little to no consistency in how and why lateral bracing is specified or detailed. Most design codes recognize that adding lateral bracing—the diagonal bracing between the bottom flanges of a typical I-girder bridge superstructure—changes the load path of an I-girder bridge sufficiently to mimic the increased stiffness and fatigue life performance of a much more expensive steel box beam superstructure. Still, lateral bracing is rarely used or, if used, not accounted for in the structural capacity of the structure. This is often because the maximum benefit is found with superstructures with few deep girders in the cross section, and far less benefit is seen for shallower multigirder cross sections. Additionally, accounting for the structural benefit of the lateral bracing increases the complexity of the bridge analysis model and precludes the use of simplified line-girder methods. For these reasons, the investigation showed that even when lateral bracing is used for reasons such as construction stability, it is rarely accounted for as a primary load carrying member in new structures. Since the inclusion of lateral bracing provides no structural benefit but also adds dead load and structural analysis complexity, most agencies attempt to eliminate lateral bracing from their structures and simply increase the capacity of the I-girders. However, for existing two-girder composite bridges, an approach is presented in which the careful addition of a new or structural consideration of existing bottom lateral bracing on an existing two I-girder superstructure could improve the live load distribution and reduce fatigue live load stress ranges sufficiently enough for the structure to remain in service without further structural strengthening.
dc.publisherAmerican Society of Civil Engineers
dc.titleHow Lateral Bracing is Used for New and Rehabilitated Composite I-Girder Bridges across Europe and North America
dc.typeJournal Article
dc.journal.volume30
dc.journal.issue3
dc.journal.titleJournal of Structural Design and Construction Practice
dc.identifier.doi10.1061/JSDCCC.SCENG-1644
dc.journal.fristpage04025061-1
dc.journal.lastpage04025061-8
dc.page8
dc.treeJournal of Structural Design and Construction Practice:;2025:;Volume ( 030 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record