Show simple item record

dc.contributor.authorKhaled A. A. Mohamad
dc.contributor.authorPeter M. Steffler
dc.contributor.authorDavid Z. Zhu
dc.date.accessioned2025-08-17T22:47:36Z
dc.date.available2025-08-17T22:47:36Z
dc.date.copyright7/1/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.otherJHEND8.HYENG-14217.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4307457
dc.description.abstractOdor complaints are widely reported due to hazardous gases being released from sewer systems. Mitigating and controlling the emission of these gases is the key to a better air environment. Existing airflow system models rely on limited, uncontrolled experiments lacking air pressure measurements. Water surface drag and wall friction coefficients are the main parameters used to calibrate these models, and they should be determined precisely for better model efficiency. The key dimensionless parameters influencing these coefficients are identified and listed as the nominal Froude and Reynolds numbers, a dimensionless pressure gradient term, headspace height to diameter ratio, and relative roughness height of the wall and water surface, calculated based on the water surface velocity and pipe diameter. A three-dimensional computational fluid dynamics model is developed to explore the effect of those parameters, assuming the air-water interface as a moving boundary in Couette flows. The resulting airflow regimes are analyzed using the produced air velocity profiles. Three regimes are identified: two are characterized as conduit pressurized flow with minor adjustments at the boundaries, and the last one includes the typical case for air movement in sewer networks. The value of the water drag coefficient is between 0.002 and 0.01, while the wall friction coefficient ranges from 0.015 to 0.045 for typical sewer conditions. This study provides an understanding of airflow dynamics and an accurate way to determine average air velocity, water drag, and wall friction coefficients in practical cases. The error from using a single value for both coefficients at any pressure gradient is assessed and reduced.
dc.publisherAmerican Society of Civil Engineers
dc.titleInfluence of Water Drag and Headspace Air Pressure on Airflow in Sanitary Sewers
dc.typeJournal Article
dc.journal.volume151
dc.journal.issue4
dc.journal.titleJournal of Hydraulic Engineering
dc.identifier.doi10.1061/JHEND8.HYENG-14217
dc.journal.fristpage04025011-1
dc.journal.lastpage04025011-14
dc.page14
dc.treeJournal of Hydraulic Engineering:;2025:;Volume ( 151 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record