Show simple item record

dc.contributor.authorFujun Niu
dc.contributor.authorYunhu Shang
dc.contributor.authorJing Luo
dc.contributor.authorMinghao Liu
dc.contributor.authorZeyong Gao
dc.contributor.authorKun Yuan
dc.contributor.authorDonggen Chen
dc.date.accessioned2025-08-17T22:42:38Z
dc.date.available2025-08-17T22:42:38Z
dc.date.copyright3/1/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.otherJCRGEI.CRENG-884.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4307332
dc.description.abstractA cast-in-place pile foundation, widely utilized in the permafrost regions of the Qinghai–Tibet Plateau, boasts superior load-bearing capacity, effectively mitigating the seasonal freeze–thaw effects. In permafrost regions, substantial pile foundation load-bearing capacity is provided by freezing strength, with the freezing strength determined by the temperature of the surrounding permafrost. In modern times, global warming has been causing permafrost degradation, posing a risk to the safety of existing pile foundations. In order to maintain the stability of these foundations, it is crucial to release excess ground heat, considering the temperature-dependent freezing strength of the ground to pile shaft. Two-phase closed thermosyphons (TPCTs) have demonstrated strong performance in the realm of cooling permafrost engineering. In this study, TPCTs were utilized to mitigate the impact of permafrost degradation by installing them around a concrete pile in order to cool the foundation ground. Following this installation, a model experiment was carried out, which ingeniously focused on analyzing the cooling performance, the process of cold energy dissipation, and the cooling scope of the TPCT pile. The study's findings indicate that the operation time of the TPCT pile accounted for about 50% of the entire freeze–thaw cycle. This device could effectively cool the surrounding foundation soil within a specified area. The TPCT pile exhibited a low temperature advantage of 0.36°C in comparison with the scenario without TPCT in terms of surrounding geotemperature, although it experienced significant cold energy dissipation. The conclusions drawn from this study have significant value for maintaining piles in permafrost regions.
dc.publisherAmerican Society of Civil Engineers
dc.titleCooling Effect of Two-Phase Closed Thermosyphons on a Cast-In-Place Pile Foundation in a Permafrost Region
dc.typeJournal Article
dc.journal.volume39
dc.journal.issue1
dc.journal.titleJournal of Cold Regions Engineering
dc.identifier.doi10.1061/JCRGEI.CRENG-884
dc.journal.fristpage04024042-1
dc.journal.lastpage04024042-10
dc.page10
dc.treeJournal of Cold Regions Engineering:;2025:;Volume ( 039 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record