Fluid–Thermal–Structural Interactions on a Supersonic Two-Dimensional Intake
View/ Open
Date
2025Author
Yuan Lin
Chibing Shen
Chenglong Wang
Mingbo Sun
Dongcai Tan
Ang Su
Banglei Guan
Zhang Li
Minggang Wan
Metadata
Show full item recordAbstract
This study aims to enhance the verification database for fluid–thermal–structural interaction (FTSI) experiments and develop a comprehensive methodology for parameter measurement in such tests. A complex S-shaped wedge model was selected to perform a 40-s FTSI experiment, and the effects of varying Mach numbers (Ma∞) on FTSI were analyzed using a validated numerical code. The results confirm the feasibility of the experimental approach, demonstrating that the proposed method captures temporal variations in key parameters and verifies the accuracy of the custom-developed simulation code. The results show that although the S-shaped wedge experiences significant parameter changes during the initial phase of the test, these parameters stabilize at different times rather than concurrently. Furthermore, an increase in Mach number (Ma∞) intensifies FTSI effects, resulting in higher component temperatures, accelerated achievement of steady-state conditions, increased temperature gradients within components, greater structural deformation, and more pronounced variations in wall pressure distribution. It is suggested that increasing Ma∞ in future FTSI experiments will amplify observable phenomena, providing more pronounced insights into the interaction dynamics.