• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Tests on Short Outer Tube–Stiffened CFDST Columns: Effect of Stiffener Distribution on Axial Performance

    Thumbnail
    View/Open
    JSENDH.STENG-14487.pdf (5.193Mb)
    Date
    2025
    Author
    Aamir Hassan
    Javed A. Bhat
    Fayaz A. Sofi
    Mohammad Adil Dar
    Metadata
    Show full item record
    Abstract
    Previous studies on concrete-filled double-skin tubular columns (CFDSTCs) have demonstrated a superior axial performance when outer steel tubes are reinforced with steel stiffeners. As a result, recommendations for stiffener design, specifically focusing on its cross-sectional area parameter, were proposed. However, as the steel tube diameter increases, increasing only the stiffener area (while maintaining a constant number of stiffeners) may satisfy the proposed recommendation, yet it could be ineffective in serving the intended purpose. Subsequently tests were conducted to address this issue through experimental investigation, as no tests or data are available for the optimal stiffener distribution in CFDSTCs, in continuation with the previous experimental research on outer tube–stiffened CFDSTs. The key focus of this study is to assess the impact of stiffener distribution in outer tubes of circular CFDSTs, by varying the stiffener width, stiffener number, outer tube diameter and stiffener spacing in terms of subpanel width. Failure characteristics in steel tubes, concrete core, peak loads, axial load–strain response, hoop-strain behavior, confined concrete strength, strength index and ductility index were the different performance indicators analyzed. Lastly, the peak test strengths were compared with those predicted by available design models, revealing inconsistencies in these approaches. The test findings highlight the significant impact of stiffener distribution on axial performance across all indicators, especially on the axial strength (up to 24%) and confined concrete strength (up to 28%). Consequently, results from a modified design model that integrated the improved confined concrete strength of short circular outer tube–stiffened CFDSTCs agreed well with the test results.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4306806
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV