dc.contributor.authorYecheng Dai
dc.contributor.authorGary M. Raftery
dc.contributor.authorKrishanu Roy
dc.contributor.authorIman Hajirasouliha
dc.contributor.authorZhiyuan Fang
dc.contributor.authorBoshan Chen
dc.contributor.authorJames B. P. Lim
dc.date.accessioned2025-08-17T22:17:21Z
dc.date.available2025-08-17T22:17:21Z
dc.date.copyright2/1/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.otherJSENDH.STENG-13833.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4306718
dc.description.abstractThe use of cold-formed steel (CFS) built-up sections for portal frames is gaining popularity due to their ability to provide sustainable solutions and more optimized section design opportunities. This paper presents an experimental and numerical investigation conducted on a novel unsymmetrical CFS built-up stiffened box beam. The sections are manufactured with a complex arrangement of stiffeners and have an overall web depth of up to 550 mm. In the literature, to our best knowledge, no large-scale bending testing has been conducted on CFS beams of such dimensions. A total of 12 full-scale four-point bending tests are reported. Nonlinear elasto-plastic finite element (FE) models were developed and validated against the experimental test results. A comprehensive parametric study involving 200 FE models was conducted to investigate the effects of key design parameters on the flexural capacity performance. The parameters included section thickness, screw spacing, and unrestrained beam length. It was found that, for the sections investigated, lateral-torsional buckling was not observed when the unrestrained length was less than 4 m. The results were then compared against the design flexural capacities determined by the American Iron and Steel Institute (AISI S100) and Australian and New Zealand Standards (AS/NZS 4600). The current design flexural capacities were conservative by 7% on average compared with the experimental and FE results. Finally, new design equations were proposed, and a reliability analysis was conducted to assess the feasibility of the proposed equations.
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental and Numerical Investigation on Flexural Behavior of Novel Unsymmetrical Cold-Formed Steel Built-Up Stiffened Box Sections
dc.typeJournal Article
dc.journal.volume151
dc.journal.issue2
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/JSENDH.STENG-13833
dc.journal.fristpage04024212-1
dc.journal.lastpage04024212-14