• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Shear Strength of Coupled Autoclaved Aerated Concrete Confined Masonry Walls

    Thumbnail
    View/Open
    JSENDH.STENG-13764.pdf (3.403Mb)
    Date
    2025
    Author
    Jorge Varela-Rivera
    Juan Cacep-Rodriguez
    Luis Fernandez-Baqueiro
    Joel Moreno-Herrera
    Metadata
    Show full item record
    Abstract
    The in-plane shear behavior of autoclaved aerated concrete (AAC) confined masonry walls has been studied considering only cantilever walls. In coupled walls, there are changes in the bending moments and axial forces of individual confined walls because of the presence of coupling beams. Those changes have not been considered in current shear design recommendations for AAC confined walls. The objective of this work was to study the shear behavior of coupled AAC walls. A total of four reduced-scale walls were tested under in-plane reverse cyclic lateral loads. In this study, 1- and 2-story-high coupled walls were considered. Coupled walls consisted of individual AAC confined walls and reinforced concrete coupling beams. Two aspect ratios were considered for the individual AAC confined walls. It was observed that the cracking pattern of the 1- and 2-story coupled walls was similar, respectively. The shear strength of individual AAC confined walls increased as the aspect ratio decreased, the shear span over the wall length ratio decreased, or the axial compressive force increased. Similarly, the shear strength and stiffness of coupled walls increased as the aspect ratio of individual AAC confined walls decreased and the shear span over the wall length ratio decreased. On the contrary, the drift ratio of coupled walls increased as the aspect ratio of individual confined walls increased and the shear span over the wall length ratio increased. A design shear strength equation was proposed for AAC confined walls. This equation is a function of the shear span over the wall length ratio. The proposed equation predicted well the experimental shear strength and can be used for cantilever and coupled AAC confined walls.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4306711
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV