Show simple item record

dc.contributor.authorSon, Juchan
dc.contributor.authorBrouman, Mohsen
dc.contributor.authorPyo, Yeongmin
dc.contributor.authorRicher, Patrick
dc.contributor.authorJodoin, Bertrand
dc.contributor.authorHong, Zekai
dc.date.accessioned2025-04-21T10:37:08Z
dc.date.available2025-04-21T10:37:08Z
dc.date.copyright1/29/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.issn0742-4795
dc.identifier.othergtp_147_09_091013.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4306562
dc.description.abstractEstablishing a continuous cooling film is an effective way to thermally protect hot-gas path components of gas turbines. For aero-engines, effusion cooling is the state-of-the-art method for developing cooling films. However, the cooling film generated by this method is far from ideal, as discrete miniature cooling air jets exiting from effusion cooling holes leave large gaps between cooling holes without adequate cooling film protection. Furthermore, effusion cooling jets can experience strong liftoff from component surfaces and are subsequently diluted due to mixing with the main flow. Recent advances in additive manufacturing (AM) technologies have enabled the fabrication of porous materials with precisely engineered lattice structures, significantly enhancing the film cooling effectiveness of hot-gas path components through transpiration cooling. A prior study has demonstrated highly promising transpiration cooling results by using a family of lattice geometries referred to as triply periodic minimal surface (TPMS) lattices. The present study experimentally investigates the influence of various TPMS lattice orientations on the film cooling effectiveness. Three types of TPMS structures, namely, diamond, Koch, and gyroid, are compared to demonstrate that the TPMS lattice orientation angle affects transpiration cooling performance, with different levels of sensitivity according to the TPMS structure. The TPMS lattice structures studied in this investigation are fabricated by stereolithography (SLA) three-dimensional printing. The adiabatic cooling film effectiveness (AFE) is measured using pressure sensitive paint (PSP).
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffects of Lattice Orientation Angle on TPMS-Based Transpiration Cooling
dc.typeJournal Paper
dc.journal.volume147
dc.journal.issue9
dc.journal.titleJournal of Engineering for Gas Turbines and Power
dc.identifier.doi10.1115/1.4067378
dc.journal.fristpage91013-1
dc.journal.lastpage91013-12
dc.page12
dc.treeJournal of Engineering for Gas Turbines and Power:;2025:;volume( 147 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record