• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Mechanisms and Robotics
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Mechanisms and Robotics
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    On the Use of Tension Transition Zones for Kinematic and Compliance Performance Analysis of Wire-Actuated Continuum Robots

    Thumbnail
    View/Open
    jmr_17_6_061013.pdf (1.570Mb)
    Date
    2025
    Author
    Shihora, Neel
    Lawson, Jared
    Moubarak, Paul
    Reese, Maximilian
    Wang, Long
    Simaan, Nabil
    Metadata
    Show full item record
    Abstract
    Wire-actuated/tendon-actuated mechanisms suffer from discontinuity in their performance measures stemming from the limitation of unilateral actuation due to tendon actuation (pull-only actuation). Using traditional Jacobian-based performance measures ignores these limitations and can underestimate the expected position/orientation (pose) uncertainty for a given design. In this paper, we put forth the notion of wire-tension transition zones, and we illustrate how these tension transition zones can be used to modify the definition of the traditional Jacobian when calculating the expected robot performance in terms of dexterity, end-effector pose uncertainty and compliance. We use wire-actuated continuum robots as an illustrative robot architecture. We compare the expected performance of three-wire versus four-wire designs while considering somewhat realistic design parameters drawn from surgical robotics as an application domain. The results of our simulation studies emphasize the importance of carefully using the reduced Jacobin with tension transition zones to capture the performance measure discontinuities due to wires/tendons going slack. Furthermore, the results show that the traditional approach underestimates the uncertainty in the position of the end-effector by as much as 50% (effects of joint-level uncertainty) and 206% (compliance performance analysis) in the case of a three-wire design alternative. We believe that this contribution supports medical robotic system designers in architecture selection and comparative design performance analysis while avoiding unpleasant surprises that would otherwise be encountered if traditional performance measures were used.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4306408
    Collections
    • Journal of Mechanisms and Robotics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV