Show simple item record

dc.contributor.authorLi, Haiyuan
dc.contributor.authorHe, Tian
dc.contributor.authorYang, Mingda
dc.contributor.authorChao, Minghui
dc.contributor.authorZhang, Qinjian
dc.contributor.authorSong, Hongxing
dc.date.accessioned2025-04-21T10:25:30Z
dc.date.available2025-04-21T10:25:30Z
dc.date.copyright1/20/2025 12:00:00 AM
dc.date.issued2025
dc.identifier.issn1942-4302
dc.identifier.otherjmr_17_6_065001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4306164
dc.description.abstractUltrasound-guided percutaneous puncture technology has advantages such as intra-operative real-time imaging, noninvasive operation, high targeting accuracy, nonionizing radiation, and low cost. However, traditional percutaneous puncture surgery requires doctors to hold ultrasound probes or puncture needles, which causes complex operations. In this article, by integrating ultrasound and needle insertion mechanisms, an ultrasound-guided miniature puncture robot is proposed. This robot can work without an external navigation or industrial or cooperative manipulator after hand-eye calibration and acknowledge the coordinate relationship between the ultrasound image and the robot tip. A three degrees-of-freedom (DoFs) of in-plane mechanism using linear actuators is designed so that the puncture needle can always be scanned by ultrasound during the operation, ensuring real-time monitoring. The method of planning puncture path, modeling the robot kinematics, and ultrasound hand-eye calibration are proposed. To track a needle in an ultrasound image, the image recognition and filter algorithm for the needle tip are presented. The accuracy of the robot puncture operation is verified by point targeting and path tracking experiments in the water tank and phantom, and the puncture error of the robot is 1.5 ± 0.5 mm in the water tank, 1.98 mm in the abdominal phantom, and 1.41 mm in the breast phantom. Finally, the work of this article effectively improves the availability and effectiveness of the ultrasound-guided puncture robot.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAn Ultrasound-Guided Miniature Hand-Eye Integrated Robot for Percutaneous Needle Placement
dc.typeJournal Paper
dc.journal.volume17
dc.journal.issue6
dc.journal.titleJournal of Mechanisms and Robotics
dc.identifier.doi10.1115/1.4067530
dc.journal.fristpage65001-1
dc.journal.lastpage65001-10
dc.page10
dc.treeJournal of Mechanisms and Robotics:;2025:;volume( 017 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record