    Evaluation of Irregular Motion in Endovascular Treatment

    Thumbnail
    View/Open
    jesmdt_008_02_021204.pdf (1.921Mb)
    Date
    2025
    Author
    Kobayashi, Kengo
    Takashima, Kazuto
    Toma, Naoki
    Mori, Koji
    Metadata
    Show full item record
    Abstract
    Vascular intervention using guidewires and catheters has been widely performed, but the selection of appropriate device manipulation is often based on the experience and skills of the surgeon. Occasionally, accidents occur due to unexpected movements of these device tips, resulting in vascular damage. To address the challenge of unpredictable device motions and the associated risk of vessel wall damage, this study aims to investigate how different vessel shapes influence device motions. Additionally, we seek to identify effective manipulation techniques to mitigate these risks. We conducted experiments involving the insertion of a guidewire and a catheter into crank-shaped blood vessel phantom models with three different bending angles. Throughout the experiment, the movement of the inserted guidewire within the blood vessel phantoms was recorded using video recording. It was discovered that jumping distance and number of jumps increased as the distance between the catheter and guidewire tip increased. In experiments with a small bending angle, guidewire jumping was infrequent, but when it occurred, jumps tended to be longer (4.0 ± 2.4 mm). Conversely, experiments involving large bending angles showed short consecutive jumps, with the last jumping distance typically being a relatively longer (2.5 ± 1.3 mm). These findings indicate that irregular motions can be reduced by keeping a catheter close to a guidewire tip. Moreover, when the bending angle is large, a manipulator should be ready to prevent further motions as soon as they notice a small first jump.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305775
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV