• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Turbomachinery
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Turbomachinery
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Conjugate Heat Transfer Validation of an Optimized Film Cooling Configuration for a Turbine Vane Endwall

    Thumbnail
    View/Open
    turbo_147_3_031011.pdf (2.345Mb)
    Date
    2024
    Author
    Yang, Xing
    Wu, Hang
    Feng, Zhenping
    Metadata
    Show full item record
    Abstract
    In this study, to improve overall cooling performance for the endwall of a turbine nozzle guide vane that incorporated internal jet impingement and external purge flow and discrete injection cooling, the external film cooling was re-designed based on the knowledge of film coverage patterns from a baseline design, allowing film injection to overcome the crossflow and to cover more areas of the endwall with a given amount of coolant. Experimental conjugate heat transfer validation of the newly designed cooling geometry was conducted in a linear vane cascade by measuring overall cooling effectiveness over the endwall through an infrared (IR) thermography technique and detecting aero-thermal fields at the cascade exit with five-hole and thermocouple probes. For a given total coolant flowrate, the influence of coolant split among different cooling sources was examined. Additionally, parallel computational simulations were undertaken to elaborate the results observed in the experiments by offering in-passage flow physics. Comparisons with the baseline design proved that the newly designed cooling scheme improved the endwall overall cooling performance in terms of both effectiveness levels and coverage. In addition to optimizing the cooling geometry, more efficient usage of the coolant was found to be linked with the proper coolant split, which helped the re-designed cooling geometry to achieve an improvement of cooling effectiveness by approximately 20%. The computational simulations produced satisfactory overall cooling effectiveness, but failed to capture mixing of coolant with mainstream flow. The coolant with mainstream flow interactions visualized by the simulations provided evidence that the coolant jets from the optimized cooling scheme increased mixing flow loss but those from the pressure side suppressed the inherent vortex flow, resulting in no aerodynamic penalty as compared with the baseline cooling design.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305521
    Collections
    • Journal of Turbomachinery

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV