Show simple item record

dc.contributor.authorAlasadi, Habeeb
dc.contributor.authorChoi, Jun-Ki
dc.contributor.authorMulford, Rydge B.
dc.date.accessioned2025-04-21T10:01:23Z
dc.date.available2025-04-21T10:01:23Z
dc.date.copyright10/18/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn2642-6641
dc.identifier.otherjesbc_5_4_044501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4305332
dc.description.abstractPhotovoltaic (PV) panels installed on building rooftops yield a positive influence on the thermal performance of the building due to the shading of the PV panels, decreasing cooling loads while causing a smaller increase in heating loads. Additionally, the electrical power output of PV panels has been shown to be increased by including reflectors between PV rows, concentrating the solar flux onto the active portion of the panels. When implemented into the spaces between the rows of a roof-mounted PV array, reflectors might further improve the positive thermal effects of rooftop installed PV arrays. This work focuses on predicting rooftop heat flux and temperature for a building rooftop equipped with PV panels and reflectors. The saved energy load, additional energy load, PV power output, rooftop heat flux, and the utility factor (ratio of positive building energy impacts to negative building energy impacts) are reported parametrically for variations in the rooftop absorptivity and reflector area for three US locations. Utility factors of 375, 140, and 160 are found for Phoenix, AZ, Boise, ID, and Dayton, OH, respectively, for a reflector covering the full area between panels with a roof having a minimal absorptivity. A building in Phoenix, AZ exhibits a 15% increase in the utility factor of the PV-building system when reflectors are incorporated compared to a PV-building system without reflectors, while a building in Dayton, OH showed a 22% increase in utility factor when reflectors are included between the rows of a roof-mounted PV array.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleBuilding Energy Savings and Power Output Augmentation of Roof Mounted Photovoltaic Using Co-Located Rooftop Reflectors
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue4
dc.journal.titleASME Journal of Engineering for Sustainable Buildings and Cities
dc.identifier.doi10.1115/1.4066795
dc.journal.fristpage44501-1
dc.journal.lastpage44501-7
dc.page7
dc.treeASME Journal of Engineering for Sustainable Buildings and Cities:;2024:;volume( 005 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record