    Evaluating the Influence of Morphological Features on the Vulnerability of Lipid-Rich Plaques During Stenting

    Thumbnail
    View/Open
    bio_147_02_021007.pdf (2.397Mb)
    Date
    2025
    Author
    Colmenarez, Jose A.
    Dong, Pengfei
    Lee, Juhwan
    Wilson, David L.
    Gu, Linxia
    Metadata
    Show full item record
    Abstract
    Lipid-rich atheromas are linked to plaque rupture in stented atherosclerotic arteries. While fibrous cap thickness is acknowledged as a critical indicator of vulnerability, it is likely that other morphological features also exert influence. However, detailed quantifications of their contributions and intertwined effects in stenting are lacking. Therefore, our goal is to assess the impact of plaque characteristics on the fibrous cap stress and elucidate their underlying mechanisms. We analyzed the stent deployment in a three-dimensional patient-specific coronary artery reconstructed from intravascular optical coherence tomography (IVOCT) data using the finite element method. Additionally, we performed sensitivity analysis on 78,000 distinct plaque geometries of two-dimensional arterial cross section for verification. Results from the three-dimensional patient-specific model indicate strong correlations between maximum fibrous cap stress and lipid arc (r=0.769), area stenosis (r=0.550), and lumen curvature (r=0.642). Plaques with lipid arcs >60 deg, area stenosis >75%, and lumen curvatures >5 mm−1 are at rupture risk. While we observed a rise in stress with thicker lipid cores, it was less representative than other features. Fibrous cap thickness showed a poor correlation, with the sensitivity analysis revealing its significance only when high stretches are induced by other features, likely due to its J-shaped stress–stretch response. Contrary to physiological pressure, the stent expansion generates unique vulnerable features as the stent load-transferring characteristics modify the plaque's response. This study is expected to prompt further clinical investigations of other morphological features for predicting plaque rupture in stenting.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305172
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV