• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Turbomachinery
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Turbomachinery
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Scale Cooling—A Novel Fractal Cooling Structure for Turbine Vanes

    Thumbnail
    View/Open
    turbo_147_6_061012.pdf (2.254Mb)
    Date
    2024
    Author
    Chi, Zhongran
    Wang, Longfei
    Metadata
    Show full item record
    Abstract
    Additive manufacturing technology provides the possibility of more efficient turbine cooling structures. In this work, a novel structure for turbine air-cooled vane based on fractal structure, named scale cooling structure, was proposed. Fractal channel arrays are arranged on the leading edge, pressure side, and suction side of the novel vane. The design of the fractal channel units takes into account the internal cooling effect, film cooling effect, manufacturing accessibility of the channels, and adaptability to non-uniform thermal loads. The initiated cooling structure allows for the use of larger wall thickness to improve strength. A parameterized design and automated mesh generation technique based on in-house code was developed for the vanes installed with a scale cooling structure. And typical turbine vanes with impingement-film cooling structure and scale cooling structure were evaluated by both infrared (IR) measurement and conjugate heat transfer (CHT) computational fluid dynamics (CFD) analysis. Experimental studies have shown that the local overall cooling effectiveness at the leading edge of the scale cooling structure vane is obviously improved compared to the prototype design with impingement-film structure. The consistency between the IR measurements and the CHT CFD results is favorable. It is found that the improvement in cooling performance of scale cooling structure is mainly due to the improvement of film cooling. Its internal cooling relies on enhanced heat transfer at the branching positions of fractal channels. The scale cooling structure is more sensitive to insufficient coolant supply pressure. It is suggested that the entire pressure difference between the cooling air and the mainstream shall be utilized by the scale cooling structure, which can provide sufficient backflow margin while enhancing internal cooling.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305146
    Collections
    • Journal of Turbomachinery

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV