    Modifying School Courtyard Design to Optimize Thermal Conditions and Energy Consumption in a Hot Arid Climate

    Thumbnail
    View/Open
    JAEIED.AEENG-1813.pdf (5.019Mb)
    Date
    2024
    Author
    Muna Salameh
    Metadata
    Show full item record
    Abstract
    This research focuses on schools due to their significant energy consumption. It explores the use of well-designed unshaded courtyards as a passive design strategy in hot climate regions, an area that has received limited attention. The research methodology combines a qualitative approach, case study, and computer simulations through ENVI-met and Integrated Environmental Solutions Virtual Environment (IESve) software. The case study involves an existing school building in the hot arid climate of the United Arab Emirates (UAE). The ENVI-met software evaluates changes in the school’s microclimate and building temperature resulting from modifications to the courtyard’s design, encompassing five phases. Moreover, the research employs the predicted mean vote (PMV) metric to assess outdoor thermal comfort within school courtyards, correlating with the five design phases. The IESve software assesses the reduction in cooling sensible load achieved through improved courtyard design in the case study. The simulation results demonstrate that the optimal courtyard design lowers the school building’s temperature by 1.9°C and 1.7°C on September 21 and March 21, respectively, compared with the base case. Furthermore, it enhances PMV within the courtyard, providing students with a more comfortable outdoor environment during breaks, with maximum PMV reductions of 1.2 and 1.1 on September 21 and March 21. In addition, the optimal courtyard design achieves a significant reduction in cooling sensible load, showing a 19% decrease on September 21 and a 27% decrease on March 21, compared with the basic case. These findings underscore the potential of well-designed courtyards to enhance thermal comfort and energy efficiency in schools within hot arid climates, contributing to sustainable architectural practices.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4304960
    Collections
    • Journal of Architectural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV