• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Architectural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Architectural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Fire Performance of Cedar Shingles under Radiant Heat

    Thumbnail
    View/Open
    JAEIED.AEENG-1751.pdf (1.531Mb)
    Date
    2024
    Author
    Hannah Carton
    Bronwyn Chorlton
    John Gales
    Eric B. Kennedy
    Metadata
    Show full item record
    Abstract
    Wood as a building material is a common roofing material in both contemporary homes and older properties such as heritage buildings. As a combustible material, wood can be associated with higher rates of building damage from wildfires. This study investigates the spontaneous ignition of contemporary Eastern white cedar shingles (Thuja occidentalis), a commonly used roofing product in older houses and heritage properties in Ontario. The samples were tested with a cone calorimeter under radiant heat without a spark igniter. The samples were conditioned under three moisture content categories: (1) ambient; (2) dry; and (3) wet. They were tested using incident radiative heat for 15 min or until 2 min after flameout under three heat fluxes: (1) 20 kW/m2, (2) 30 kW/m2, and (3) 40 kW/m2. Moisture content and heat flux had a clear impact on ignition and pyrolysis. All samples ignited at 40 kW/m2 and the dry samples ignited at 30 kW/m2. In samples which did not ignite, indicators of pyrolysis such as off-gassing, charring, and ember formation were delayed as the moisture content increased. However, dry samples at 40 kW/m2 had a slower average ignition time by 20 s and a lower average peak HRR than the ambient samples by 8 kW/m2. It was posited that it could be due to the char layer forming faster at the lower moisture content, creating a protective layer that delayed ignition. Future research will investigate the impact of incident heat flux and moisture content on piloted ignition of cedar shingles via firebrands, which is common during wildfires. Research to evaluate the performance and ignition of heritage cedar shingles versus contemporary cedar shingles is also recommended.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4304639
    Collections
    • Journal of Architectural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV