Show simple item record

dc.contributor.authorShiling Pei
dc.contributor.authorKeri L. Ryan
dc.contributor.authorJeffrey W. Berman
dc.contributor.authorJohn W. van de Lindt
dc.contributor.authorSteve Pryor
dc.contributor.authorDa Huang
dc.contributor.authorSarah Wichman
dc.contributor.authorAleesha Busch
dc.contributor.authorWilliam Roser
dc.contributor.authorSir Lathan Wynn
dc.contributor.authorYi-en Ji
dc.contributor.authorTara Hutchinson
dc.contributor.authorShokrullah Sorosh
dc.contributor.authorReid B. Zimmerman
dc.contributor.authorJames Dolan
dc.date.accessioned2025-04-20T10:02:54Z
dc.date.available2025-04-20T10:02:54Z
dc.date.copyright10/12/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.otherJSENDH.STENG-13752.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303895
dc.description.abstractAs part of a collaborative research effort (The NHERI TallWood Project), an extensive shake table test program was undertaken on a full-scale 10-story mass timber building with a resilient posttensioned mass timber rocking wall lateral system. Over a three-year period, academic and industry partners collaborated on the design, construction, and testing of a 34 m (113 ft) tall, 10-story mass timber building at the world’s largest outdoor shake table facility (NHERI@UC San Diego). The test building incorporated a resilient mass timber rocking wall lateral system, gravity connection details designed to remain damage-free under design level earthquakes as well as innovative nonstructural systems detailed to tolerate moderate building drifts without significant damage. A total of 88 earthquake tests at different intensity levels were conducted, including several at the risk targeted maximum considered earthquake intensity for the building’s design location. Experimental results indicate that a tall wood building with the systems and details employed in this study can withstand design basis and maximum considered earthquake level events repeatedly with no notable residual drift, no structural member or connection damage, while only experiencing moderate nonstructural damage that would be repairable, meeting the intended resilience goals. This paper provides a summary of the design, construction, testing, and primary results from this experimental program.
dc.publisherAmerican Society of Civil Engineers
dc.titleShake-Table Testing of a Full-Scale 10-Story Resilient Mass Timber Building
dc.typeJournal Article
dc.journal.volume150
dc.journal.issue12
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/JSENDH.STENG-13752
dc.journal.fristpage04024183-1
dc.journal.lastpage04024183-21
dc.page21
dc.treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record