dc.description.abstractComputational fluid dynamics (CFD) simulations are widely used to develop and analyze blood-contacting medical devices such as left ventricular assist devices (LVADs). This work presents an analysis of the transient behavior of two centrifugal LVADs with different designs: HeartWare VAD and HeartMate3. A scale-resolving methodology is followed through Large Eddy Simulations, which allows for the visualization of turbulent structures. The three-dimensional (3D) LVAD models are coupled to a zero-dimensional (0D) 2-element Windkessel model, which accounts for the vascular resistance and compliance of the arterial system downstream of the device. Furthermore, both continuous- and pulsatile-flow operation modes are analyzed. For the pulsatile conditions, the artificial pulse of HeartMate3 is imposed, leading to a larger variation of performance variables in HeartWare VAD than in HeartMate3. Moreover, CFD results of pulsatile-flow simulations are compared to those obtained by accessing the quasi-steady maps of the pumps. The quasi-steady approach is a predictive tool used to provide a preliminary approximation of the pulsatile evolution of flow rate, pressure head, and power, by only imposing a speed pulse and vascular parameters. This preliminary quasi-steady solution can be useful for deciding the characteristics of the pulsatile speed law before running a transient CFD simulation, as the former entails a significant reduction in computational cost in comparison to the latter.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTransient Performance Analysis of Centrifugal Left Ventricular Assist Devices Coupled With Windkessel Model: Large Eddy Simulations Study on Continuous and Pulsatile Flow Operation
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue10
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4065418
dc.journal.fristpage101008-1
dc.journal.lastpage101008-11
dc.page11
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail
This item appears in the following Collection(s)

Show simple item record