Show simple item record

dc.contributor.authorSharma, Sanjay
dc.contributor.authorMesnil, Olivier
dc.contributor.authorRecoquillay, Arnaud
dc.contributor.authorChapuis, Bastien
dc.date.accessioned2024-12-24T19:15:16Z
dc.date.available2024-12-24T19:15:16Z
dc.date.copyright6/13/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn2572-3901
dc.identifier.othernde_7_4_041005.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303591
dc.description.abstractSimulation has been recognized as a promising option to reduce the time and costs associated with determining probability of detection curves to demonstrate the performance of guided wave-based structural health monitoring (GW-SHM) systems. Time-domain transient spectral finite element schemes have been used for large GW-SHM simulation campaigns, but the most common piezoelectric transducer model used for actuation, the pin force model, has limitations in terms of its range of validity. This is because the excitation frequency for the pin force model has only been validated far below the first electromechanical resonance frequency of the piezoelectric transducer mainly due to not considering the normal stress and dynamics of the transducer. As a result, the value of simulation tools for performance demonstrations may be limited. To address this limitation, this paper introduces a hybrid actuator model that integrates frequency-dependent complex interfacial stresses in both the shear and normal directions, computed using finite elements. These surface stresses are compatible with time-domain transient spectral finite element schemes, enabling their seamless integration without compromising the required performance for conducting intensive simulation campaigns. The proposed hybrid actuator model undergoes validation through a combination of simulation and experimental studies. Additionally, a comprehensive parametric study is conducted to assess the model’s validity across a wide range of excitation frequencies. The results demonstrate the accurate representation of the transduction signal above the piezoelectric transducer’s first free electromechanical resonance frequency.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Hybrid Actuator Model for Efficient Guided Wave-Based Structural Health Monitoring Simulations
dc.typeJournal Paper
dc.journal.volume7
dc.journal.issue4
dc.journal.titleJournal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
dc.identifier.doi10.1115/1.4065549
dc.journal.fristpage41005-1
dc.journal.lastpage41005-11
dc.page11
dc.treeJournal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems:;2024:;volume( 007 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record