    Design of Three-Dimensional-Printed Compression Ring for Enhanced Wound Healing of Colorectal Anastomosis to Minimize Dehiscence and Leakage Post Colectomy

    Thumbnail
    View/Open
    med_018_02_021007.pdf (5.831Mb)
    Date
    2024
    Author
    Phowarasoontorn, Parima
    Rajakaruna, SojaThilini
    Nisha, Aliha
    Holter, Jesper
    Al-Ketan, Oraib
    Vega, Carlos Abril
    Barajas-Gamboa, Juan S.
    Al-Bahri, Shadi
    Ramadi, Khalil B.
    Metadata
    Show full item record
    Abstract
    Bowel resection surgery, also known as colectomy, is a primary therapeutic intervention where a neoplastic or cancerous segment of the bowel is removed and an anastomosis constructed to reestablish intestinal continuity. Several techniques can be used to create the anastomosis, including mechanical staplers or manual sutures. A potentially life-threatening complication in colon anastomosis is dehiscence and leakage. Various contributing factors can hinder the formation of anastomosis, including technical failure (human error, staple malfunction), inflammation caused by foreign body response (sutures and staples), collagenolytic bacteria, and patient comorbidities (chemotherapy, old age, and obesity). Here, we report a three-dimensional (3D)-printed compression ring with electrical stimulation (ES) functionality to improve wound healing and anastomotic closure. The device consists of a one-way locking mechanism for initial deployment, an elastic band tightening mechanism to secure seal as tissue heals, and electrodes for electrical stimulation to enhance wound healing. The compression ring was assembled with 83.4±3.9 N of force and delivers 147.5±8.8 kPa of pressure to tissue, effectively restricting blood flow to the clamped tissue. This helps to create the anastomosis between remaining tissue on either side. Our design facilitates manual assembly without necessitating an additional delivery device. Electrical impedance analysis confirmed adequate tissue–electrode contact. We tested this device with ex vivo ovine intestinal tissue and confirmed that the compression ring was able to withstand up to 2.0±0.4 kPa intraluminal pressure immediately following installation. By combining mechanical strength and electrical stimulation, this device could potentially improve wound healing, anastomotic closure, and minimize the risk of leaks.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4303567
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV