• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Miniaturized Endoscopic Device Integrating Raman Spectroscopy and Laser Speckle Technology Via an Image Fusion Algorithm for Intraoperative Identification and Functional Protection of Parathyroid Glands

    Thumbnail
    View/Open
    med_018_02_021004.pdf (2.972Mb)
    Date
    2024
    Author
    Wen, Qiye
    Cai, Chang
    Fang, Jiayi
    Luo, Zifeng
    Luo, Yuanwei
    Wang, Chong
    Liang, Weixiong
    Wang, Song
    Metadata
    Show full item record
    Abstract
    The importance of parathyroid glands (PGs) protection is increasingly recognized by thyroid surgeons in the field of minimally invasive video-assisted thyroidectomy (MIVAT). However, current techniques for intra-operative identification and vascularity assessment of the PGs are contentious and complex. This study presents the design and validation of a miniaturized device for fusion near-infrared autofluorescence (NIRAF) based on Raman spectroscopy and laser speckle contrast imaging (LSCI) via an image fusion algorithm for functional protection of PGs in the MIVAT. Our light source components include an integrated light emitting diode (LED) light source fiber, an NIRAF optical fiber, an acquisition optical fiber, and a laser speckle optical fiber in the endoscopic system to achieve identification and vascularity assessment of PGs using a single endoscopic probe. It has been validated in ex vivo tissue experiments that the fluorescence intensity detected by the device was equivalent to that of the marker indocyanine green (ICG) in visual images and superior to that of the thyroid and all other tissues in the neck. Based on clinical studies, MIVAT using functional fluorescence endoscopy, compared with the White light pattern group, the NIRAF combined with LSCI modality group increased the number of intra-operative confirmations of the PGs (P < 0.001), declined the decrease in parathyroid hormone (PTH) (P < 0.05) and calcium levels (P < 0.05) on the first postoperative day, and reduced the incidence of symptomatic hypocalcemia (P < 0.05). Our device may reduce the incidence of postoperative permanent hypoparathyroidism. Application of an miniaturized functional fluorescence endoscope for real-time and label-free PGs identification and vascularity assessment in MIVAT could be realized.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4303564
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV