Show simple item record

dc.contributor.authorCastellano, Vitale Kyle
dc.contributor.authorCommander, Jon
dc.contributor.authorBurch, Thomas
dc.contributor.authorBurch, Hayden
dc.contributor.authorRemy, Jessica
dc.contributor.authorHarman, Benjamin
dc.contributor.authorZabala, Michael E.
dc.date.accessioned2024-12-24T19:14:18Z
dc.date.available2024-12-24T19:14:18Z
dc.date.copyright5/9/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn1932-6181
dc.identifier.othermed_018_01_015001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303559
dc.description.abstractNeuropathy is associated with sensation loss in the extremities. Semmes–Weinstein monofilaments are common tools used to assess an individuals' sensation perception. It has long been characterized using hand-applied Semmes–Weinstein monofilaments, however they are subjected to clinician biases and material deviations, and other factors that affect the reproducibility to administer a consistent amount of contact force on the plantar surface. A tool was developed to automate this testing protocol and to more accurately determine an individual's threshold sensitivity at various locations on the plantar surface. Individuals without type 2 diabetes mellitus (DM2) were classed as control subjects. They were evaluated using a hand applied monofilament and the automated tool. The device accuracy of the automated tool was first determined, followed by subject's threshold sensitivity at each location. Twenty-six locations were evaluated per person between 0.35 and 10.0 grams-force. A threshold sensitivity index norm was calculated based on the threshold sensitivity at each location per individual and was plotted against age, body mass index, ankle brachial index, fasting blood sugars, and HbA1c. The device demonstrated accuracy with an absolute error less than or equal to 0.4 grams-force at most locations. Age showed the strongest relationships to sensation loss. As age increased sensitivity to touch decreased. The automated tool was shown to be effective in determining an individual's threshold sensitivity in individuals without DM2. The calculation of the threshold sensitivity index norm was useful to classify sensation loss. The automated tool has the potential to effectively diagnosis neuropathy and document disease progression.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePerformance Analysis and Clinical Evaluation of an Automated Tool for Plantar Threshold Sensitivity Assessment in a Non-Diabetic Control Population
dc.typeJournal Paper
dc.journal.volume18
dc.journal.issue1
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4065473
dc.journal.fristpage15001-1
dc.journal.lastpage15001-10
dc.page10
dc.treeJournal of Medical Devices:;2024:;volume( 018 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record