Show simple item record

dc.contributor.authorMantecón, Ramiro
dc.contributor.authorRuiz, Alvaro
dc.contributor.authorWheatley, Benjamin M
dc.contributor.authorDíaz-Álvarez, José
dc.contributor.authorMiguélez, Henar
dc.contributor.authorYoussef, George
dc.date.accessioned2024-12-24T19:10:11Z
dc.date.available2024-12-24T19:10:11Z
dc.date.copyright3/21/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_08_084502.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303416
dc.description.abstractIn this research, an experimental biomechanics construct was developed to reveal the mechanics of distal tibial fracture by submitting synthetic tibiae to cyclic loading, resulting in a combined stress state due to axial compression and bending loads. The synthetic tibia was fixed at the knee but allowed to rotate in the coronal and sagittal planes at the ankle. The first three loading regimes lasted for 4000 cycles/each, and the final until ultimate failure. After 12k±80 cycles, the observed failure patterns closely resembled distal tibial fractures. The collected data during cyclic loading were fitted into a phenomenological model to deduce the time-dependent response of the synthetic tibiae. Images were also collected and analyzed using digital image correlation to deduce the full-field state of strain. The latter revealed that longitudinal strain contours extended in the proximal–distal direction. The transverse strain contours exemplified a medial-to-lateral distribution, attributed to the combined contributions of the Poisson's effect and the flexural deformation from axial and bending components of the applied load, respectively. The experimental construct, full-field characterization, and data analysis approaches can be extended to elucidate the effect of different fixation devices on the overall mechanical behavior of the bone and validate computational models in future research.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFeasibility Study of Experimental Protocol for the Time-Dependent Mechanical Response of Synthetic Tibia
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue8
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4064974
dc.journal.fristpage84502-1
dc.journal.lastpage84502-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record