    Accurate Temperature Reconstruction in Radiofrequency Ablation for Atherosclerotic Plaques Based on Inverse Heat Transfer Analysis

    Thumbnail
    View/Open
    bio_146_08_081010.pdf (4.658Mb)
    Date
    2024
    Author
    Shu, Shuang
    Yang, Guoliang
    Han, Hengxin
    Zhan, Taijie
    Dang, Hangyu
    Xu, Yi
    Metadata
    Show full item record
    Abstract
    Radio frequency ablation has emerged as a widely accepted treatment for atherosclerotic plaques. However, monitoring the temperature field distribution in the blood vessel wall during this procedure presents challenges. This limitation increases the risk of endothelial cell damage and inflammatory responses, potentially leading to lumen restenosis. The aim of this study is to accurately reconstruct the transient temperature distribution by solving a stochastic heat transfer model with uncertain parameters using an inverse heat transfer algorithm and temperature measurement data. The nonlinear least squares optimization method, Levenberg-Marquardt (LM), was employed to solve the inverse heat transfer problem for parameter estimation. Then, to improve the convergence of the algorithm and reduce the computational resources, a method of parameter sensitivity analysis was proposed to select parameters mainly affecting the temperature field. Furthermore, the robustness and accuracy of the algorithm were verified by introducing random noise to the temperature measurements. Despite the high level of temperature measurement noise (ξ = 5%) and larger initial guess deviation, the parameter estimation results remained closely aligned with the actual values, with an overall ERMS consistently below 0.05. The absolute errors between the reconstruction temperature at the measurement points TC1, TC2, and TC3, and the actual temperature, remained within 0.33 °C, 2.4 °C, and 1.17 °C, respectively. The Levenberg-Marquardt algorithm employed in this study proficiently tackled the ill-posed issue of inversion process and obtained a strong consistency between the reconstructed temperature the actual temperature.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4303383
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV