Show simple item record

dc.contributor.authorSuresh, Ronanki
dc.contributor.authorPrakash, Ranjith
dc.contributor.authorPraveen, Visakh
dc.contributor.authorDatta, Santanu Prasad
dc.date.accessioned2024-12-24T19:04:46Z
dc.date.available2024-12-24T19:04:46Z
dc.date.copyright7/18/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0195-0738
dc.identifier.otherjert_146_10_101702.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303247
dc.description.abstractRecently, an ejector refrigeration system (ERS) has been a promising cooling strategy with waste heat utilization and minimization of power consumption by evading the compressor. However, analyzing the intricate flow structure inside the ejector and the corresponding coefficient of performance enhancement are major challenges of an ERS. The type of working fluid, design specifications, and working conditions significantly affect the ejector behavior. The environmental issues caused by the leakage of the most popular high-GWP refrigerant R134a divulge the need for low-GWP alternatives. Moreover, the effect of critical design specifications such as area ratio (AR) and nozzle exit position (NXP) for these alternatives is not explored yet. Therefore, five low-GWP alternates for R134a, namely R1234yf, R1243zf, R152a, R513a, and R440a, are tested numerically under wide-ranging operating conditions. In addition, the ejector performance for all refrigerants is examined for seven distinct ARs and five different NXPs. The effect of the refrigerant variant and NXP on the internal flow structures of the ejector is also analyzed. Besides, the study is extended to find the optimal NXP at various operating temperatures using R1234yf refrigerant. In most cases, the higher entrainment ratio (ER) is obtained with R1234yf and R1243zf, and the increase in AR has a positive effect on the ER. The impact of the NXP is higher at condenser temperature with minimal waste heat in the generator. Irrespective of the operating conditions for R1234yf, the optimum NXP is obtained as 10 mm, which is 1.67 times the constant-area mixing chamber diameter.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleNumerically Optimized Ejector Geometry for Ejector Refrigeration Systems With Low-Global Warming Potential Working Fluids
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue10
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4065729
dc.journal.fristpage101702-1
dc.journal.lastpage101702-11
dc.page11
dc.treeJournal of Energy Resources Technology:;2024:;volume( 146 ):;issue: 010
dc.contenttypeFulltext