Show simple item record

dc.contributor.authorBehrens, Roland
dc.contributor.authorZimmermann, Jan
dc.contributor.authorWang, Zechang
dc.contributor.authorHerbster, Sebastian
dc.contributor.authorElkmann, Norbert
dc.date.accessioned2024-12-24T19:00:24Z
dc.date.available2024-12-24T19:00:24Z
dc.date.copyright1/29/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_04_041001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303127
dc.description.abstractCollaborative robots (cobots) can be employed in close proximity to human workers without safety fences. The operation mode Power and Force Limiting requires that cobots not exceed the biomechanical limits of ISO/TS 15066 to ensure protection against injuries caused by collisions with them. Collision tests must be performed to prove that cobots cannot exceed the biomechanical limits. Such tests are performed with a biofidelic measuring device that measures contact forces and replicates the biomechanics of the human body. Biomechanical response curves serve as a reference for the calibration of such devices. In order to be able to compare measurements and limits correctly and reliably, the limits and response curves for calibration must be obtained from the same data with the same methodology. In this article, we present a new technique for developing biomechanical response curves, which employs a statistical model we used to calculate biomechanical limits for cobots in a previous study. This technique's development process entails normalizing the data over force, resampling them and then fitting the newly obtained samples to a log-normal distribution. The statistical model makes it possible to produce response curves for the same quantile we used for the limits. Our technique adds a confidence region around each response curve to express the sufficiency of the available data. We have produced response curves for 24 different body locations for which we have calculated limits. These curves will enable manufacturers of cobot testing equipment to calibrate their measuring devices precisely.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDevelopment of Biomechanical Response Curves for the Calibration of Biofidelic Measuring Devices Used in Robot Collision Testing
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue4
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4064448
dc.journal.fristpage41001-1
dc.journal.lastpage41001-6
dc.page6
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record