Show simple item record

dc.contributor.authorGong, Alex T.
dc.contributor.authorYau, Shi-Wen Olivia
dc.contributor.authorErickson, Hans B.
dc.contributor.authorToepfer, Rudolph J.
dc.contributor.authorZhang, Jessica
dc.contributor.authorDeschmidt, Aleah M.
dc.contributor.authorParsey, Conner J.
dc.contributor.authorNorfleet, Jack E.
dc.contributor.authorSweet, Robert M.
dc.date.accessioned2024-12-24T18:57:13Z
dc.date.available2024-12-24T18:57:13Z
dc.date.copyright11/16/2023 12:00:00 AM
dc.date.issued2023
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_01_014502.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303039
dc.description.abstractPerforming a small bowel anastomosis, or reconnecting small bowel segments, remains a core competency and critical step for the successful surgical management of numerous bowel and urinary conditions. As surgical education and technology moves toward improving patient outcomes through automation and increasing training opportunities, a detailed characterization of the interventional biomechanical properties of the human bowel is important. This is especially true due to the prevalence of anastomotic leakage as a frequent (3.02%) postoperative complication of small bowel anastomoses. This study aims to characterize the forces required for a suture to tear through human small bowel (suture pullout force, SPOF), while analyzing how these forces are affected by tissue orientation, suture material, suture size, and donor demographics. 803 tests were performed on 35 human small bowel specimens. A uni-axial test frame was used to tension sutures looped through 10 × 20 mm rectangular bowel samples to tissue failure. The mean SPOF of the small bowel was 4.62±1.40 N. We found no significant effect of tissue orientation (p = 0.083), suture material (p = 0.681), suture size (p = 0.131), age (p = 0.158), sex (p = .083), or body mass index (BMI) (p = 0.100) on SPOF. To our knowledge, this is the first study reporting human small bowel SPOF. Little research has been published about procedure-specific data on human small bowel. Filling this gap in research will inform the design of more accurate human bowel synthetic models and provide an accurate baseline for training and clinical applications.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCharacterizing the Suture Pullout Force for Human Small Bowel
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue1
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4063951
dc.journal.fristpage14502-1
dc.journal.lastpage14502-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2023:;volume( 146 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record