• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    The Sub-Metered HVAC Implemented for Demand Response Dataset

    Thumbnail
    View/Open
    ds_146_01_011107.pdf (2.405Mb)
    Date
    2024
    Author
    Lin, Austin J.
    Lei, Shunbo
    Keskar, Aditya
    Hiskens, Ian
    Johnson, Jeremiah X.
    Mathieu, Johanna L.
    Metadata
    Show full item record
    Abstract
    Closed-loop control of commercial building heating, ventilating, and air conditioning (HVAC) for demand response requires measurements used as feedback to the controllers. Demand response effectiveness is usually measured as a power deviation from baseline, but the building automation system (BAS) does not usually collect power measurements, and whole-building electric meters typically measure power at intervals of 15 min, which may be too slow for some types of demand response. Demand response strategies are sometimes focused on components of building HVAC systems, e.g., the response of supply/return fans to temperature set-point changes, but these components are usually not submetered. Fan power can be estimated from physics-based models leveraging BAS data, e.g., airflow measurements; but our ability to effectively close the loop on these estimates is not clear. In this paper, we introduce a massive dataset that contains both submetered fan power data and BAS data for several building HVAC systems during typical operation and demand response events. Through a case study we show that models leveraging BAS data alone do not provide accurate estimates of fan power during event transients, making it unlikely that closed-loop control of commercial building HVAC components for demand response would be effective using BAS data alone. This demonstrates the value of submetering HVAC components. More broadly, our dataset will enable future research bridging the gap between building control and power systems research.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4302785
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV