Show simple item record

dc.contributor.authorWenping, Peng
dc.contributor.authorQingguo, Cheng
dc.contributor.authorQiulin, Wang
dc.date.accessioned2024-12-24T18:42:10Z
dc.date.available2024-12-24T18:42:10Z
dc.date.copyright4/8/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn1948-5085
dc.identifier.othertsea_16_6_064501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4302589
dc.description.abstractHigh-porosity open-cell metal foams can be utilized to fill parallel-plate channels for achieving efficient cooling performance. A wall heat transfer model considering viscous and inertial heat effects is given based on local thermal nonequilibrium theory. Detailed investigations are conducted on influences of parameters on cooling performance. The results indicate that an optimum velocity exists; impacts of porosity and pore size depend on thermophysical properties of fluids and flow velocity; heat transfer resistance also varies with them; increasing foam thickness enhances cooling performance for air under identical velocities but has negligible effect for water; under identical flow rates, decreasing foam thickness improves cooling performance; enlarging base surface area is an effective approach at low flow velocities.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleWall Heat Transfer Characteristic of Parallel-Plate Channel Filled With Open-Cell Metal Foams in Large Flow Velocity Range
dc.typeJournal Paper
dc.journal.volume16
dc.journal.issue6
dc.journal.titleJournal of Thermal Science and Engineering Applications
dc.identifier.doi10.1115/1.4065133
dc.journal.fristpage64501-1
dc.journal.lastpage64501-6
dc.page6
dc.treeJournal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record