• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Thermal Science and Engineering Applications
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Thermal Science and Engineering Applications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Study on the Influence of Fan and Fan Cowl on Intake Air Parameters of Cooling Module

    Thumbnail
    View/Open
    tsea_16_3_031005.pdf (1.492Mb)
    Date
    2024
    Author
    Zhang, Zhenxing
    Wang, Dan
    Guo, Yue
    Shen, Lei
    Wang, Xiaodan
    Metadata
    Show full item record
    Abstract
    Due to the increase in heat load, the demand for heat dissipation of the cabin cooling module has increased. The fan arrangement and the design of the fan cowl can significantly affect the intake air parameters, thereby affecting the performance of the heat exchangers. In this paper, the whole vehicle model was set up and the effect of the fan installation distance, the fan cowl coverage ratio, and the radial extension of the fan cowl outlet was researched by numerical simulation. The results show that due to the relative position of the layout of the cooling module, the effect of the fan arrangement and the fan cowl design on the intake parameters of the radiator is greater than that of the intercooler. The improvement of the air velocity uniformity can reduce the intake air average temperature for better heat dissipation; a 2% improvement in air intake velocity uniformity can lead to a 6% reduction in air intake average temperature event at a low air mass flow. The extended installation distance of the fan or the increased closure degree of the fan cowl leads to more favorable intake parameters, thereby optimizing the cooling performance of the heat exchangers. Moreover, when the fan cowl coverage ratio reaches 0.9, the air intake average temperature increases by 5.6%, which means that the fan cowl coverage should not be too high. This study will provide useful reference information for the design of cooling modules in the cabin.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4302558
    Collections
    • Journal of Thermal Science and Engineering Applications

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV