Show simple item record

dc.contributor.authorNeptune, Andra
dc.contributor.authorMcMorran, John G.
dc.contributor.authorGregory, Diane E.
dc.date.accessioned2024-12-24T18:40:49Z
dc.date.available2024-12-24T18:40:49Z
dc.date.copyright7/16/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_11_114503.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4302549
dc.description.abstractThis study sought to evaluate the effects of prolonged cyclic loading on the tissue-level mechanical properties of the spinal annulus fibrosus. Functional spinal units (FSUs) were obtained from porcine cervical spines at the C3–C4 and C5–C6 levels. Following a 15-min preload of 300 N of axial compression, the FSUs were split into three groups: the cyclic loading group cycled between 0.35 MPa and 0.95 MPa for 2 h (n = 8); the static loading group was compressed at 0.65 MPa for 2 h (n = 10); and a control group which only underwent the 300 N preload (n = 11). Following loading, samples of the annulus were excised to perform intralamellar tensile testing and interlamellar 180 deg peel tests. Variables analyzed from the intralamellar test were stress and strain at the end of the toe region, stress and strain at initial failure (yield point), Young's modulus, ultimate stress, and strain at ultimate stress. Variables evaluated from the interlamellar tests were lamellar adhesion strength, adhesion strength variability, and stiffness. The analysis showed no significant differences between conditions on any measured variable; however, there was a trend (p = 0.059) that cyclically loaded tissues had increased adhesion strength variability compared to the static and control conditions. The main finding of this study is that long-duration axial loading did not impact the intra- or interlamellar mechanical properties of the porcine annulus. A trend of increased adhesion strength variability in cyclically loaded samples could indicate a potential predisposition of the annulus to delamination.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHow Static and Cyclic Loading Affect the Mechanical Properties of the Porcine Annulus Fibrosus
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue11
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4065841
dc.journal.fristpage114503-1
dc.journal.lastpage114503-5
dc.page5
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record