• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Geotechnical and Geoenvironmental Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Geotechnical and Geoenvironmental Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Field Evaluation of the Installation and Pullout of Snakeskin-Inspired Anchorage Elements

    Thumbnail
    View/Open
    JGGEFK.GTENG-12311.pdf (3.032Mb)
    Date
    2024
    Author
    Alejandro Martinez
    Fabian Zamora
    Daniel Wilson
    Metadata
    Show full item record
    Abstract
    Soil nails and tieback anchors are used extensively for excavation support and slope stabilization; however, their performance can be complicated by limited pullout capacity or installation challenges. This paper presents the results of field load tests performed on anchorage elements with snakeskin-inspired surfaces that do not require grout and that can reduce the force required for installation. These tests evaluated the effects of the asperity geometry, soil type, and embedment depth on the anchor load transfer behavior and pullout capacity. The tests consisted of jacked installation and pullout loading in sites consisting of dense sand and structured silt. The test results in sand indicate that the installation force and pullout skin friction increase as the asperity height is increased and the asperity length is decreased. The pullout capacity of the snakeskin-inspired anchors in sand was between 1.2 and 4.2 times greater than the capacity of a reference rough anchor. In the structured silt site, disturbance during installation influenced the pullout behavior, resulting in a decrease in anchor capacity as the asperity height was increased. However, the anchor capacity with small asperity heights was greater than that of the reference rough anchor. The snakeskin-inspired anchors mobilized direction-dependent skin friction, resulting in pullout skin friction values that were as much as 3.0 and 4.5 times greater than those generated during installation in the sand and silt sites, respectively, due to mobilized passive resistances during pullout. The results indicate that the snakeskin-inspired anchors can outperform conventional driven anchors in sands. However, the possible effects of installation disturbance should be evaluated carefully in sensitive, structured soils.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4298971
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV