dc.contributor.authorMaciej Kulpa
dc.contributor.authorTomasz Howiacki
dc.contributor.authorMateusz Rajchel
dc.contributor.authorTomasz Siwowski
dc.contributor.authorŁukasz Bednarski
dc.date.accessioned2024-12-24T10:18:52Z
dc.date.available2024-12-24T10:18:52Z
dc.date.copyright10/1/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.otherJCCOF2.CCENG-4418.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4298687
dc.description.abstractFiber-reinforced polymer (FRP) composites are promising materials already being used in bridge construction. Lightweight deck panels, mainly used in the rehabilitation or replacement of existing bridges, are the most commonly used FRP bridge components. However, FRP decks are prone to damage due to delamination, matrix cracking, interlaminar cracking, and debonding. In addition, due to their microstructure, FRP materials tend to deteriorate in ways that are not easily detected by visual inspection. Therefore, nondestructive methods should often complement visual inspections aimed at assessing the technical condition of the structure. New measurement techniques are constantly being researched and developed to assist in the evaluation of FRP structures. Distributed fiber optic sensing (DFOS) has been chosen as the main measurement technique of the newly developed FRP bridge deck panel because this technique provides extended advantages compared to the conventional spot gauges. The concept of a component with an integrated DFOS-based system capable of structural control and detection of overloaded vehicles has been developed and verified both in laboratory conditions. The novelty of the presented approach is that sensors (strain-sensing fibers) are precisely embedded in FRP laminates for simultaneous internal strain and vertical displacement (shape change) measurements and delamination detection. The experimental verification of a full-scale deck under static and dynamic loading is described in the paper. The performance of the DFOS system was verified using reference techniques. The results proved the system to be a reliable tool for diagnosing FRP bridge decks.
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental Verification of GFRP Bridge Deck Panels Using an Integrated Distributed Fiber Optic Sensing System
dc.typeJournal Article
dc.journal.volume28
dc.journal.issue5
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/JCCOF2.CCENG-4418
dc.journal.fristpage04024042-1
dc.journal.lastpage04024042-19
dc.page19