    Impact of Prescriptive Fire Design Provisions on Embodied Carbon for Mass Timber and Hybrid Mass Timber Floors

    Thumbnail
    View/Open
    JAEIED.AEENG-1695.pdf (1.653Mb)
    Date
    2024
    Author
    Samantha Leonard
    Kevin Parfitt
    Ryan Solnosky
    Metadata
    Show full item record
    Abstract
    Structural mass timber has been used more often in buildings over the last 5 years, given its potential to be a sustainable alternative. However, concerns still exist around the fire safety of mass timber structures, and current mass timber building designers must consider a variety of fire protection strategies, including but not limited to noncombustible protection and design for sacrificial char thickness. This research focuses on better understanding how prescriptive code fire protection strategies affect the sustainability goals that have partially driven mass timber use. This paper studies how decisions during early design can reduce embodied carbon (EC), the initial energy use of a structure’s construction. Five structural floor system types were modeled parametrically for various levels of fire protection. System types included timber–concrete composites, cross-laminated timber (CLT)–steel hybrids, and all-timber systems. The resulting EC data analysis reveals that all-timber systems perform the best for EC when the fully protected option is used at shorter spans, when the combined approach option is used at midrange spans, and when the fully exposed timber option is used at longer spans. Across all studied systems, the shallowest possible depth occurred for the 10-ft (3.05-m) spanning CLT–steel hybrid systems at 11.5 in. (292 mm) deep for the fully protected system, and the lowest possible EC was 10.5 lb CO2 eq/ft2 (51.3 kg CO2 eq/m2) for the fully protected 10-ft (3.05 m) all-timber system.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4298594
    Collections
    • Journal of Architectural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV