    Consequence-Oriented Fire Intensity Optimization for Structural Design under Uncertainty

    Thumbnail
    View/Open
    10.1061-JSENDH.STENG-12645.pdf (986.3Kb)
    Date
    2024/04/01
    Author
    Andrea Franchini
    Carmine Galasso
    Jose L. Torero
    Metadata
    Show full item record
    Abstract
    The first step in current methodologies for the (probabilistic) performance-based fire safety design and assessment of structures is characterizing fire hazard scenario(s). Next, structural response analysis is performed to estimate hazard consequences in terms of damage or loss metrics of interest. These metrics are eventually appraised to verify whether various performance objectives are achieved and design iterations are needed. Nevertheless, such approaches rely on preliminary assumptions on the structural configuration and features characterizing scenarios used as thermal inputs. Consequently, they do not fully exploit the fire–structure coupling effect, where fire affects a structure, and the characteristics of the structure also affect the combustion process and fire dynamics. Indeed, the structural design choices define the fire scenarios that could potentially affect the structural and nonstructural performance. This paper introduces a consequence-oriented fire intensity optimization (CFO) approach to the fire safety design of structures to address such limitations. The proposed approach considers fire scenarios as additional design variables and delivers them as procedure outputs, optimizing the balance between increasing structural capacity and decreasing fire intensity. Furthermore, it evaluates the effect of input uncertainties through Monte Carlo sampling. A single-span bridge subject to a car fire is used to showcase the proposed approach. For this case study, it is shown that fire scenario characteristics (fuel bed and traffic load positions, heat release rate history) maximizing consequences are strongly correlated to the structural features and cannot be set a priori. Finally, design decisions exploiting the described coupling effect to achieve various performance objectives are discussed. Overall, the proposed approach highlights the benefits of enhancing the fire and heat transfer model’s capability to capture the fire–structure coupling effect for achieving more optimized design solutions.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296796
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV