• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Cyclic Testing and Repair of Coupled CLT Walls with Steel Link Beams

    Thumbnail
    View/Open
    10.1061-JSENDH.STENG-12498.pdf (5.130Mb)
    Date
    2024/02/01
    Author
    Ben Moerman
    Minghao Li
    Alessandro Palermo
    Tobias Smith
    Hyungsuk Lim
    Metadata
    Show full item record
    Abstract
    Coupled cross-laminated timber (CLT) walls with steel link beams are a type of high-capacity lateral load resisting system for multistory buildings. In this study, a 6.6 m tall coupled CLT wall specimen with three steel link beams and mixed-angle screwed hold-downs was tested to ±4.5% drift to evaluate its cyclic performance. The system achieved peak strengths of +590 and −592  kN, while also exhibiting relatively high displacement ductility factors of 7.6 and 6.9 in the positive and negative directions, respectively. Failure of the system was characterized by combined bending and withdrawal of the mixed-angle screws in the hold-downs, yielding and eventual inelastic buckling of the steel link beams, CLT toe crushing, and local CLT delamination. In comparison with similar cantilever CLT shear walls, the coupled wall system exhibited 45% greater peak strength, dissipated approximately 50% more energy, and experienced less degradation of its energy dissipation capacity on repeated load cycles (when subjected to the same loading protocol). Following the initial test, the steel link beams, screw hold-downs, and damaged CLT regions were repaired, then the wall specimen was retested with the same loading protocol. The repaired wall behaved similarly to the original test and exhibited slightly higher energy dissipation and peak strength but more rapid strength deterioration under cyclic loading. The retesting provided evidence that it may be feasible to repair the coupled wall system after an earthquake because the damage was localized, and the main CLT wall elements were effectively protected from damage.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296771
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV