Show simple item record

dc.contributor.authorTommy D. Bounds
dc.contributor.authorKanthasamy K. Muraleetharan
dc.contributor.authorGerald A. Miller
dc.contributor.authorBo Zhang
dc.contributor.authorAmirata Taghavi
dc.contributor.authorZachary Bright
dc.contributor.authorWalter L. Peters
dc.contributor.authorRoyce W. Floyd
dc.contributor.authorJeffery Volz
dc.date.accessioned2024-04-27T22:25:49Z
dc.date.available2024-04-27T22:25:49Z
dc.date.issued2024/02/01
dc.identifier.other10.1061-JPCFEV.CFENG-4518.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296634
dc.description.abstractThermally induced stresses can build up in rigid pavements without pressure relief joints. The pressure created becomes a problem for adjacent structures such as bridges. The pressure can cause the pavement to push on the bridge and close the bridge expansion joints. This sets the stage for additional distress if not repaired quickly. This paper presents a case study where excessive pavement pressure damaged a two-span conventional bridge spanning Interstate 35 in Moore, Oklahoma. The bridge was instrumented with vibrating wire sensors to gather information on the behavior of the bridge before and after the repairs. There is a dearth of sensor verified observations of excessive pavement pressure acting on conventional bridges. The sensor data provided in-depth information on the response of the distressed bridge before and after repairs to thermal loading. Prior to the repairs the approach pavement was pushing on the bridge deck and causing the abutment backwalls to tilt toward the bridge. Following the repairs, the approach pavement is no longer pushing on the bridge deck. However, the abutment backwall is now moving in response to thermal changes in the bridge deck, likely due to excessive friction between the deck and the abutment backwall. U-shaped shaped cracking and spalling, previously observed in integral abutment bridges, was observed at this conventional abutment bridge, and the mechanisms causing these cracks and spalling are discussed. Through this study it was found that placement of pavement pressure relief joints relative to the bridge is crucial for reducing the magnitude of stress acting on the bridge. It was also found that the pavement stress acting on a bridge deck can be estimated with vibrating wire strain gauges given a baseline strain response for the approach pavement.
dc.publisherASCE
dc.titleExcessive Approach Pavement Pressure against Conventional Bridges
dc.typeJournal Article
dc.journal.volume38
dc.journal.issue1
dc.journal.titleJournal of Performance of Constructed Facilities
dc.identifier.doi10.1061/JPCFEV.CFENG-4518
dc.journal.fristpage04023066-1
dc.journal.lastpage04023066-9
dc.page9
dc.treeJournal of Performance of Constructed Facilities:;2024:;Volume ( 038 ):;issue: 001
dc.contenttypeFulltext


Files in this item