Show simple item record

dc.contributor.authorHaoyang, Liu
dc.contributor.authorQiang, Du
dc.contributor.authorQingzong, Xu
dc.contributor.authorGuangyao, Xu
dc.contributor.authorHongye, Li
dc.contributor.authorDawei, Chen
dc.contributor.authorSong, Liu
dc.contributor.authorSiyi, Wang
dc.date.accessioned2024-04-24T22:51:07Z
dc.date.available2024-04-24T22:51:07Z
dc.date.copyright3/12/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0889-504X
dc.identifier.otherturbo_146_8_081006.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295987
dc.description.abstractA laidback fan-shaped hole is commonly used due to its superior lateral film coverage. Its discharge coefficient is significantly influenced by internal crossflow owing to its complex geometrical structure. In this paper, the authors numerically investigate the flow mechanisms of the laidback fan-shaped hole under the influence of internal crossflow. The numerical simulations utilize the validated SST k–ω turbulence model, with the Reynolds number of internal crossflow ranging from 20,000 to 160,000 and the ratio of pressure ranging from 1 to 1.6. The results show that the different orientations of internal crossflow cause varying degrees of in-hole separation that led to a discrepancy in the discharge coefficient. The larger the Reynolds number of the crossflow is, the more drastic the change in the discharge coefficient. Furthermore, a comparison between the results obtained with and without internal crossflow has shown that the length of the cylindrical section is the primary factor determining the discharge coefficient of the laidback fan-shaped hole. The magnitude of the discharge coefficient depended on the extent of flow separation within the cylindrical section. Additionally, the numerical simulations obtained the discharge coefficient under a high internal crossflow Reynolds number of internal crossflow and a wall with a constant thickness and compared it with the predictions of a low-dimensional model of the discharge coefficient (based on our previous experimental data). The discrepancy between the results is within 10%, thus verifying the scalability of the low-dimensional model.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffect of the Key Geometry and Flow Parameters on Discharge Coefficient of Laidback Fan-Shaped Hole Under Coolant Crossflow Condition
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue8
dc.journal.titleJournal of Turbomachinery
dc.identifier.doi10.1115/1.4064837
dc.journal.fristpage81006-1
dc.journal.lastpage81006-17
dc.page17
dc.treeJournal of Turbomachinery:;2024:;volume( 146 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record