Show simple item record

dc.contributor.authorStraub, Douglas
dc.contributor.authorWeber, Justin
dc.contributor.authorRoy, Arnab
dc.contributor.authorLee, Chien-Shing
dc.contributor.authorShih, Tom I-P.
dc.date.accessioned2024-04-24T22:50:43Z
dc.date.available2024-04-24T22:50:43Z
dc.date.copyright1/16/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0889-504X
dc.identifier.otherturbo_146_5_051011.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295973
dc.description.abstractCounter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. The hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue5
dc.journal.titleJournal of Turbomachinery
dc.identifier.doi10.1115/1.4064316
dc.journal.fristpage51011-1
dc.journal.lastpage51011-15
dc.page15
dc.treeJournal of Turbomachinery:;2024:;volume( 146 ):;issue: 005
dc.contenttypeFulltext


Files in this item