Show simple item record

dc.contributor.authorVeley, Emma M.
dc.contributor.authorThole, Karen A.
dc.contributor.authorBogard, David G.
dc.date.accessioned2024-04-24T22:49:45Z
dc.date.available2024-04-24T22:49:45Z
dc.date.copyright11/16/2023 12:00:00 AM
dc.date.issued2023
dc.identifier.issn0889-504X
dc.identifier.otherturbo_146_3_031006.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295948
dc.description.abstractCooling components in the hot section of a gas turbine are essential to component durability. Common methods of cooling include rib turbulators in internal passages and film cooling on external surfaces. The holes that produce the film cooling are fed from the internal channels often containing ribs. Consequently, there is an interdependence of internal heat transfer and external film cooling. The purpose of this study was to obtain a better understanding of the interaction of ribs and film cooling. To quantify the cooling performance, the surface temperatures were measured, from which overall effectiveness was calculated. For the experiments, additively manufactured test coupons were made of Inconel 718 to match engine Biot numbers. These test coupons had internal feed channels with and without ribs and had both cylindrical holes and meter-diffuser-shaped holes with 15 deg lateral expansion angles and a 1 deg forward expansion angle. A single rectangular channel was one type of feed channel. The other type of feed channel was individual circular channels, with each circular channel supplying an individual film-cooling hole. The experimental results showed that the circular individual channels have 80% higher baseline overall effectiveness than the single rectangular channels without any film cooling. Ribbed turbulators without film cooling also increased the overall effectiveness by 21% for single rectangular channels and by 29% for the circular individual channels compared to the respective non-ribbed channels. While the film cooling increased the overall effectiveness of all geometries, the single rectangular channels had increased overall effectiveness levels by up to twice that of the no film-cooling case. On average, the single rectangular channels had an 80% improvement from film cooling, whereas the individual channel feeds, on average, had only a 50% improvement, given their high baseline effectiveness levels.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Effects of Channel Supplies on Overall Film-Cooling Effectiveness
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue3
dc.journal.titleJournal of Turbomachinery
dc.identifier.doi10.1115/1.4063927
dc.journal.fristpage31006-1
dc.journal.lastpage31006-11
dc.page11
dc.treeJournal of Turbomachinery:;2023:;volume( 146 ):;issue: 003
dc.contenttypeFulltext