• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Condensation Heat Transfer Experiments of R410A and R32 in Horizontal Smooth and Enhanced Tubes

    Thumbnail
    View/Open
    sol_146_3_031004.pdf (2.144Mb)
    Date
    2023
    Author
    Feng, Wei
    Gao, Yu
    Li, Wei
    Li, Junye
    Cao, Yanlong
    Li, Tianwen
    Sherif, S. A.
    Ma, Lianxiang
    Ke, Hanbing
    Metadata
    Show full item record
    Abstract
    A horizontal smooth copper tube and two enhanced tubes (a dimpled tube and a diamond-shaped tube) with a length of 2 m and an outer diameter of 9.52 mm were studied in a two-phase condensation experiment using R410A and R32 as heat transfer working fluids. The condensation heat transfer performance of different heat transfer tubes at various mass fluxes ranging from 150 to 400 kg/(m2s) and different vapor qualities ranging from 0.8 to 0.2 was studied experimentally. For R410A, the heat transfer coefficients (HTCs) of the dimpled tube and the diamond-shaped tube were found to be 1.39–1.52 times and 1.30–1.35 times higher than those of the smooth tube, respectively. For R32, the HTCs were found to be 1.46–1.59 times higher for the dimpled tube and 1.26–1.35 times higher for the diamond-shaped tube than for the smooth tube. The diamond-shaped tube was found to be effective in directing the flow of the liquid phase and in thinning the liquid film thickness. The dimpled tube was found to promote droplet entrainment and disturbance. Both of those effects contributed to improving the HTCs in the two enhanced tubes investigated. The HTCs of R410A were found to be lower than those of R32 because of the smaller specific heat capacity, smaller latent heat of condensation, and relatively poorer thermal conductivity of R410A. Taking the combined effect of heat transfer and pressure drop into account, a performance enhancement factor (PEF) was computed and was found to range from 0.9 to 1.51. Based on the experimental data collected, a new empirical correlation equation has been proposed with a maximum error band of 10%. Flow pattern maps for the tested tubes have also been generated and are presented in the paper. Both of the two enhanced tubes were found to promote the development of annular flow. The HTCs were found to be highest when the flow pattern was of the annular flow type.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295831
    Collections
    • Journal of Solar Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV